User's Manual Part 4

RBS 2308 and RBS 2309 User’s Guide
11 Reconfiguring the RBS for IP Transmission
11.1 Introduction
This chapter describes how to reconfigure the RBS 2308 for IP Transmission.
Installing a Packet-Switched Termination Unit (PSTU) enables the RBS to carry
traffic over an Internet Protocol (IP) network.
When an RBS 2308 is configured with a PSTU for IP-based transmission, a
maximum of four Transceivers (TRX) can be used.
Reconfiguration c an be done either in-house or on-site.
Note that the instructions in this chapter include information about the optical
Ethernet interface that is not supported in the first software release.
11.1.1 Target Groups
This chapter is for the following groups:
RBS installation personnel
Site test and integration personnel
11.2 Preconditions
Before starting the reconfiguration, ensure that the following conditions are met:
The chapters Personal Health and Safety Information and System Safety
Information have been read
Tools for RBS maintenance are available (see chapter Tools and
Instruments, section Equipment for Maintenance in RBS 2308 and
RBS 2309 User’s Guide)
Site Installation Documentation is available
The BTS software supporting IP-based transmission is stored in both
memory locations of the RBS
11.3 Reconfiguration Procedure
This section describes the order in which the reconfiguration is performed.
2