User's Manual Part 4
RBS 2308 and RBS 2309 User’s Guide
14.
Press the Local/Remote button on the IXU to set the RBS to remote
mode. Wait until the R F off indicator on the RRU interface panel goes
off and the Operational indicator shows a constant light.
15.
Close the sunshi
elds.
Handling Replaced Units
The TIM should be returned to Ericsson for repair with a repair delivery note,
LZF 084 84 (Blue Tag) attached. Include a clear description of the fault
found. See Section 10.6 Returning Hardware on page 255 for instructions
on completing a repair delivery note.
10.5.12 Replacing a Y-Link Cable
This section describes how to replace a faulty Y-link cable.
Taking the RRU out of Service
1.
Open the sunshields.
2.
Contact the
OMC operator to obtain permission to take the TRXs
connected t
o the RRU out of service temporarily. Wait until the RF off
indicator s
hows a constant light.
3.
Press the Local/Remote button
on the RRU to set the unit to
local mode. Wait until the local
indicator on the RRU shows a
constant light.
250 EN/LZT 720 0027 Uen R8A 2006-06-27