User's Manual Part 3

RBS 2308 and RBS 2309 User’s Guide
Putting the RBS into Operation
23.
Switch on the AC power and DC power.
24.
Close the RRU.
25.
Inform the OMC operator that the applicable c ells are to be put into
service.
26.
Press the Local/Remote button on the IXU to set the RBS to remote
mode. Wait until the RF off indicator on the RRU interface panel goes
off and the O perational indicator comes on.
27.
Close the sunshields.
Handling Replaced Units
The IXU should be returned to Ericsson for repair with a repair delivery note,
LZF 084 84 (Blue Tag) attached. Include a clear description of the fault
found. See Section 10.6 Returning Hardware on page 255 for instructions
on completing a repair delivery note.
10.5.5 Replacing an MCB
This section describes how to replace a faulty MCB.
Caution!
Sharp metal edges may exist that can cause cuts to the skin or clothing. Wear
protective gloves when handling this equipment.
Taking the RRU out of Service
1.
Open the sunshie
lds.
2.
Contact the OMC operator to obtain permission to temporarily take
the TRXs connected to the RRU out of service. Wait until the RF off
indicator shows a constant light.
2
25
EN
/LZT 720 0027 Uen R8A 2006-06-27