User's Manual Part 3

RBS 2308 and RBS 2309 User’s Guide
Transmission OK
If a TIM is used and a
green Transmission OK port indicator is off, even though
transmission is ex
pected, then perform the following actions step-by-step until
the fault ceases:
Ensure that the TIM is properly mounted, and the selector switch for
transmission impedance selection is set correctly for each port
Ensure that the transmission cables have been properly connected to the
right port in the IXU, and each cable thread connected to the correct inlet
Note: The order of the ports in the IXU is: A C B D.
Ensure that the external transmission equipment is working properly and
that cables are connected correctly
Swap the cable thread pairs
Perform a transmission test, see c hapter RBS Site Integration
Check the transmission cable. If it is faulty, replace it
Replace the IFB, see Section 10.5.3 Replacing an IFB on page 215.
If a PSTU is used, then follow the instructions in the following
OPI:
E1 Interface Down 9/1543-LZA 701 0001
10.4.3 Corrective Actions on the RRU
Fault
If the red Fault indicator is on, an RRU HW fault(s) is detected. Perform the
following actions step-by-step until the fault ceases:
Use the OMT to display fault information, see Section 10.3.1 Reading Fault
Status on page 177
Operational
If the green Operational indicator is double-flashing, software is being
downloaded. If the indicator is flashing, configuration is in progress. A software
download from the BSC can take 30 60 minutes, a software download from
theIXUflashcard5–10minutes,andaconfigurationlessthan5 minutes.
Wait until all activity is finished, that is, until the flashing stops.