User's Manual Part 3

RBS 2308 and RBS 2309 User’s Guide
Note: Do not under a
ny circumstances touch the RBS while a function change
is in progress, whi
ch is indicated by a double-flashing Operational
indicator.
10.4.2 Corrective Actions for t he IXU
Fault
If the red Fault indicator is on, IXU HW fault(s) are detected. Perform the
following actions step-by-step until the fault ceases:
If a PSTU is used and the red Fault indicator on the PSTU is on, see the
PSTU Alarm OPI corresponding to the alarm that was issued from the
PSTU.
Use the OMT to display fault information, see Section 10.3 Fault
Localization Using OMT on page 176. If the OMT cannot be connected,
then proceed with the steps below
Ensure that the flash card has been properly inserted in the IXU
Replace the IDB and software on the flash card, see Section 10.5.2
Replacing a Flash C ard on page 210
Replace the flash card, see Section 10.5.2 Replacing a Flash Card on
page 210
Replace the IXU, see Section 10.5.4 Replacing an IXU on page 219
Operational
If the green Operational indicator is double-flashing, software is being
downloaded. If the indicator is flashing, configuration is in progress, for
example, synchronization. A software download from the BSC can take 30 60
minutes and synchronization 5 10 minutes. Wait until all activity is finished,
that is, until the flashing stops.
Local
If the yellow Local indicator i s on and it is not possible to bring the IXU into
remote mode, either by using the OMT or by pressing the IXU Local/Remote
button, then perform the following actions step-by-step until the fault ceases:
Reset the IXU
Install a new IDB using the OMT, see chapter Site Installation Tests
Replace the IXU. See Section 10.5.4 Replacing an IXU on page 219
196