User's Manual Part 2
RBS 2308 and RBS 2309 User’s Guide
Table 55 Indicator
Status
Status
Indicator
During Restart
After Restart
Operational Off Flashing: on 2 s, o
ff 0.2 s
(remote operatio
n mode)
Fault Red
(first few seconds)
Off
9.
Verify the settings for each of the attributes.
Command: getMoAttribute
Example: getMoAttribute PST=0 wakeUpEventInterval
8.3.4 Checking Status
This section describes how to check the PSTU status after putting the PSTU
into remote operation.
For more information on PSTU alarms and actions to be taken, see:
PSTU Alarm OPIs
1.
Check the indicators on the PSTU. For more information o n indicator
status, see chapter Maintenance in the RBS 2308 and RBS 2309
User’s Guide.
2.
Check the PSTU log for alarms.
Command: log read
Example: log read
8.3.5 Verifying Remote Operation
To verify remote operation an OSS operator must be contacted to confirm that
the PSTU can be remotely operated from the OSS.
8.3.6 Performing Concluding Routines
This section describes the necessary concluding routines after the PSTU has
been put into remote operation.
158
EN/LZT 720 0027 Uen R8A 2006-06-27