User's Manual Part 2
RBS 2308 and RBS 2309 User’s Guide
Note: Using the OMT
, always reload the software and install the appropriate
IDB after moving a u
sed flash card to another cabinet. This ensures
consistent softwa
re and correct configuration.
Note: The RBS must
be in Local mode in order to accept a new or modified
IDB.
Note: Do not touch
the RBS when any indicators are double-flashing. See
section Double-F
lash Indication of Function Changes in chapter
Maintenance.
1. Physically conn
ect the OMT to the RBS if not already connected. See
Section 7.6.2 Co
nnecting OMT on page 118.
2. On the RBS 2000 me
nu, select Connect to connect the OMT logically
to the RBS.
3. On the Configur
ation menu, click Install IDB.
If the OMT detec
ts inconsistencies between the RBS HW and the IDB, then
the difference
s will be displayed in a window. However, the IDB in the RBS
can still be ov
erwritten if an RBS/IDB inconsistency has been detected.
The IXU and RRU
s remain in Local Mode after the IDB has been installed.
4. On the Configu
ration menu, click Site Specific Data and Display to open
the site_spec
ific_data.txt - window. Check that the c orrect parameters
have been def
ined.
7.7 Reading Fault Status
This section describes how to read the fault status, using the OMT. If any fault
indicator on the RBS is on, fault status must be read.
1. Read the IDB if it has not already been read. See Section 7.6.3 Reading
IDB on page 118.
2. On the Maintenance menu, click Monitor to open the Monitor window.
See figure below.
140
EN/LZT 720 0027 Uen R8A 2006-06-27