User's Manual Part 2
RBS 2308 and RBS 2309 User’s Guide
3. In the OMT dialog bo
x asking “Do you really want to overwrite the IDB
data in the OMT?”, c
lick Yes.
4. In the OMT dialog box asking “Do you want to re-use data in the previous
configuration?”, click Yes if the IDB is to be modified only, and No if a
new IDB is to be configured.
7.6.2 Connecting OMT
This section describes how to connec t the OMT physically to the RBS.
1. Remove the lid from the OMT port on the IXU.
2. Connect the OMT cable from the PC serial port to the OMT port on the
right-hand side of the IXU. If an extended OMT cable is connected to the
OMT port, then connect the OMT cable to the end of the extended OMT
cable.
P010276B
L
o
c
a
l/R
e
m
o
te
IX
U
te
m
p
.
A
C
p
o
w
e
r o
n
D
C
p
o
w
e
r o
n
T
ra
n
s
m
is
s
io
n
O
K
P
o
r
t A
P
o
r
t B
P
o
r
t C
P
o
r
t D
OMT Cable
Figure 51 Connecting OMT to IXU
3. Start the OMT.
7.6.3 Reading IDB
This s ection describes how to read the IDB in the OMT to check if the values of
the IDB parameters are correct.
1. On the RBS 2000 menu, select Connect to connect the OMT logically
to the RBS.
2. On the Configuration menu, select Read IDB.
3. On the Configuration menu, select Display and then Information to enter
the Display Information window.
118
EN/LZT 720 0027 Uen R8A 2006-06-27