User Manual

Table Of Contents
RBS 2107
The figure below provides an overview of the power distribution system in the
RBS 2107.
ACCU
PSUs
IDM
BFU
DC/DC
Internal
battery
Internal
DC users
Climate
DF
DC filter
and OVP
AC mains
External
battery
Outside
RBS cabinet
Inside
RBS cabinet
DC out
TM equipment
P012639A
Figure 10 Power System
7.1 Power Supply
This section describes the AC mains power supply, the external earth-fault
circuit breakers
, and the mains fuses.
AC Mains Supply Voltage
Single-phase, two-phase, or three-phase AC can be used.
Table 13 Power P
arameters
Nominal Voltag
e
200 250 V AC
Operating Voltage
180 275 V AC
Nominal Frequency 50 60 Hz
Operating Frequency
45 65 Hz
Maximum Inrush Current (Total,
All Phases)
60 A for 10 ms (typical duration)
PSU Capacity
3 × 1200 W (3600 W total)
BFU 1 × 200 A
23 (28)
EN/LZT 720 0491 Uen R2A