User Manual
Table Of Contents
- toc
- RBS 2107
- 1 Product Overview
- 2 Dimensions
- 3 Space Requirements
- 4 Environment
- 5 Hardware Units
- 6 Interfaces
- 8 Transmission
- 9 External Alarms
- 10 Standards, Regulations and Dependability
- RBS 2107
- tables
- Table 1 RBS 2107 Weights
- Table 2 RBS 2107 Colours
- Table 3 Climatic Requirements
- Table 4 Compliance Boundary Dimensions for the General Public (G
- Table 5 Characteristics for a Typical Antenna (KRE 101 1916/1)
- Table 6 Maximum Power to Antenna for Various RBS 2107 Configurat
- Table 7 Cable Gland Capacity
- Table 8 Optional Configurations in the DF
- Table 9 OVP Modules Capacity
- Table 10 Antenna Connections
- Table 11 External Connections
- Table 12 Switches and Circuit Breakers
- Table 13 Power Parameters
- Table 14 Mains Fuses Recommendation
- Table 15 Output Power
- Table 16 Power Consumption
RBS 2107
P012632A
A2
A6
A4
A5
A3
A1
Figure 9 Antenna Connections
Table 10 Antenna Connections
Connection Number Connection To Type of Connector
A1 – A6 Antenna 7-16" IEC 169-4
Other External Connections
Table 11 External Connections
Connection
Location
Connection To Type of Connector
AC
connection
box
AC mains connections Screw terminal for wires 2.5 – 16
mm
2
ACCU AC service outlet • IEC 83:1975 standard C 2b
(Sweden, Germany, and others)
• IEC 83:1975 standard B2, same
as BS 1363:1984 standard 13A
(UK)
• IEC 83:1975 standard A5-15
(USA)
• SEV 1011 S 24507
(Switzerland)
Reference
earth
Earthing connection M8 screw, 50 mm
2
stranded
copper wire
20 (28)
E
N/LZT 720 0491 Uen R2A