User Manual

Table Of Contents
RBS 2107
Connection
field 1
Connection
field 3
Connection
field 2
Connection
field 4
Power inlet
P012696A
102
360
457
898
1000
115
393
274
557
710
Unit of measurements: mm
Figure 8 Cable Inlet Measurements
Table 7 Cable Gland Capacity
Connection Field Cables
1 See Antenna Connections on Page 19
2 7 × 12 mm (diameter) OVP
1 × 15 mm (diameter) GPS
1 × (17 20 mm) (diameter) DC out
3 6 × (1 × 10 mm +
3 × 0.5 mm) (diameter)
4 1 × (17 28 mm) (diameter) AC Connection
Connections on DF
The DF is a modular construction containing seven OVP modules for PCM
links, external alarms, DC out (100 W), and ESB cables.
Optional Configurations in the DF
The table below shows the options that can be used simultaneously through the
OVP modules in the DF. DC out and GPS can always be used independently of
the number of PCM lines, external alarms, and ESB configurations.
18 (28)
E
N/LZT 720 0491 Uen R2A