User Manual

Table Of Contents
Ericsson Internal
DESCRIPTION 5 ( 34 )
/ XSNSIXI 19/1551-LZA 701 0001 Uen
CBC/ XRX/M ( Kai Lian) 2011-05-05 G
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
48 to 60 V DC
120–250 V AC (50/60 Hz) and +24 V DC
+24 V DC, without Power Supply Unit (PSU)
2.3 Optional Equipment
The equipment listed below is available, but is not necessary for basic
functionality.
Antenna Sharing Unit (ASU)
Splitter unit
Battery backup, external only
Bias injectors
Distribution Frame (DF), externally mounted
Dual-Duplex Tower-Mounted Amplifier (ddTMA), externally mounted
Digital Cross-Connect (DXX), transmission equipment
External Synchronization Bus (ESB)
Hybrid Combiner Unit (HCU)
Redundant PSU
Tower-Mounted Amplifier Control Module (TMA-CM)
Transmission Adapter (TA), 75–120
3 Dimensions
This section describes the physical characteristics of the RBS.
For dimensions, see Figure 1.
Weight
Table 1 Weights
Unit Weight
RBS cabinet
(1)
230 kg (507 lbs)
Base frame 12 kg (26 lbs)
(1) Fully equipped including base frame.