Characteristic
Description
Range +20.5 to +29.0 V DC
Non-destructive range +0 to +32 V DC
Inrush current Max. 500 A (0.1–10 ms)
RBS 2206 +24 V DC Fuses
Table 13 Fuse Specifications
Minimum for Safe
Function
Recommended for
Maximum Selectivity
Maximum Allowed
Fuse Rating
1 × 160 A
(1)
1 × 200 A 1 × 250 A
(1) Can be used when no transmission or optional equipment is installed.
RBS 2206 V2 +24 V DC Fuses
Table 14 Fuse Specifications
Minimum for Safe
Function
Recommended for
Maximum Selectivity
Maximum Allowed
Fuse Rating
1 × 160 A 1 × 200 A 1 × 300 A
8.3 48 V DC to 60 V DC Power
Table 15 Requirements
Characteristic
Description
Nominal 48 or 60 V DC
Range 40.0 to 72.0 V DC
Non-destructive range +0 to 80 V DC
Inrush current 200 A (0.1–5 ms)
RBS 2206 48 V DC to 60 V DC Fuses
Table 16 Fuse Specifications
Minimum for Safe
Function
Recommended for
Maximum Selectivity
Maximum Allowed
Fuse Rating
4 × 32 A 4 × 35 A 4 × 40 A