The fan control is integrated in the DXU and controls the fans in the cooling
system by regulating fan speed.
Number of units: 1
IDM-11
This variant of the Internal Distribution Module (IDM) is a panel for distributing
the internal +24 V DC power to the various units. Each distribution circuit in
the cabinet is connected to an IDM circuit breaker.
Number of units: 1
PSU
Two types of Power Supply Unit (PSU) are available:
PSU-AC-32, a variant of the PSU that converts AC to DC (PSU-AC), which
converts 120–250 V AC to regulated +24 V DC
PSU-DC-32, a variant of the PSU that converts DC to DC (PSU-DC), which
converts
48 V DC or 60 V DC to regulated +24 V DC
Number of units: 0–3
6.3 Optional Hardware Units
This section describes the optional hardware units available for the RBS 2206
and RBS 2206 V2.
ASU-01
The Antenna-Sharing Unit (ASU) is part of co-siting, that is, using another
cabinet together with a GSM RBS cabinet in the same sector. The ASU allows
a TDMA (or other) cabinet and a GSM RBS cabinet to share RX antennas.
Number of units: 0–1
Bias Injector
The bias injectors are mounted directly on the CDU antenna connectors.
Number of units: 0–6
BBS
The RBS can be provided with a Battery Backup System (BBS) from an
external cabinet.