User Manual
Table Of Contents
- toc
- RBS Product Description
- 1 Introduction
- 2 Product Overview
- 3 Dimensions
- 4 Space Requirements
- 5 Environment
- 6 Hardware Units
- 7 Interfaces
- 8 Power System
- 9 Transmission
- 10 External Alarms
- 11 Standards, Regulations and Dependability
- RBS Product Description
- tables
- Table 1 Weights
- Table 2 Colour
- Table 3 Environmental Specifications
- Table 4 Compliance Boundary Dimensions for the General Public (G
- Table 5 Characteristics for a Typical Antenna (KRE 101 1916/1)
- Table 6 Maximum Power to Antenna for Various RBS Configurations
- Table 7 RBS 2206 External Connections
- Table 8 RBS 2206 V2 External Connections
- Table 9 AC Power Requirements
- Table 10 Fuse Specifications
- Table 11 Fuse Specifications
- Table 12 +24 V DC Power Requirements
- Table 13 Fuse Specifications
- Table 14 Fuse Specifications
- Table 15 Requirements
- Table 16 Fuse Specifications
- Table 17 Fuse Specifications
- Table 18 Power Consumption RBS 2206
- Table 19 Power Consumption RBS 2206 V2
Ericsson Internal
DESCRIPTION 9 ( 34 )
/ XSNSIXI 19/1551-LZA 701 0001 Uen
CBC/ XRX/M ( Kai Lian) 2011-05-05 G
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
Footprint
Unit of measurement: mm
P008315A
(RBS 2202)
RBS 2206
FRONT
99
400
598
220
45
320
400
o 20x75
Figure 3 Drilling Pattern
The RBS 2206 has the same footprint as the RBS 2202 cabinet. The base
frame is used as a template to mark new holes. If an RBS 2202 is being
replaced by an RBS 2206, the holes for the old cabinet can be used for the
new cabinet.
The RBS 2206 V2 uses the same base frame as the RBS 2206.
5 Environment
The RBS is designed to operate within limits stated for climatic requirements
and also to have a limited effect on the environment.
5.1 Operating Environment
The climatic requirements for the RBS on the site are shown in the table below.
Table 3 Environmental Specifications
Environmental
Parameters
Normal
Operation
(1)
Safe Functio
n
(2)
Non-destructive
Conditions
(3)
Temperature
+5 to +40 C
0 to +45 C
-10 to +55 C
Relative Humidity
5 – 85% 5 – 90% 5 – 90%