- tables
- Table 1 RBS Weights with Combined Climate Unit
- Table 2 RBS Weights with Heat Exchanger Climate Unit
- Table 3 RBS 2106 Colours
- Table 4 RBS 2106 Climatic Requirements
- Table 5 RBS 2106i and RBS 2106 V3 Climatic Requirements
- Table 6 Sound Pressure Level, Bystander Position without Sound H
- Table 7 Sound Pressure Level, Bystander Position with Sound Hood
- Table 8 Sound Pressure Levels for a Free Standing RBS with Combi
- Table 9 Sound Pressure Levels for an RBS against a Wall, with Co
- Table 10 Sound Pressure Level, Bystander Position without Sound
- Table 11 Sound Pressure Level, Bystander Position with Sound Hoo
- Table 12 Sound Pressure Levels for a Free Standing RBS€2106 with
- Table 13 Sound Pressure Levels for an RBS€2106 Against a Wall, w
- Table 14 Sound Pressure Level, Bystander Position without Sound
- Table 15 Sound Pressure Levels for a Free Standing RBS 2106i or
- Table 16 Sound Pressure Levels for an RBS 2106i or RBS€2106€V3 w
- Table 17 Compliance Boundary Dimensions for the General Public (
- Table 18 Characteristics of Typical Antenna
- Table 19 Maximum Power to Antenna for Various RBS€2106 Configura
- Table 20 Maximum Dimensions
- Table 21 Power Distribution for the TM Space
- Table 22 Connection Field Inlets in RBS 2106i and RBS 2106 V3
- Table 23 OVP Module Capacity
- Table 24 Overvoltage Arrestors
- Table 25 Antenna Connections
- Table 26 External Connections
- Table 27 Optical Indicators
- Table 28 Switches and Circuit Breakers
- Table 29 Power Parameters
- Table 30 Mains Fuses Recommendation
- Table 31 Output Power
- Table 32 Maximum Power Consumption during Battery Charging
Ericsson Internal
DESCRIPTION 18 ( 50 )
/ XSNSIXI 129/1551-LZA 701 0001 Uen
CBC/ XRX/M ( Kai Lian) 2011-05-05 F
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
Table 12 Sound Pressure Levels for a Free Standing RBS 2106 with Heat Exchanger
Calculated Distance in Metres, Each Direction
Without Sound Hood With Sound Hood
Temp.
Sound
Pressur
e Level
dBA
Front Left Right Back Front Left Right Back
35 10
7755555
40
5
4433333
50 <1 <1 <1 <1 <1 <1 <1 <1
15
60 <1 <1 <1 <1 <1 <1 <1 <1
35 19 13 13 8 8
777
40 11
77
44444
50 2 2 2<1<1<1<1<1
20
60 <1 <1 <1 <1 <1 <1 <1 <1
35 31 21 21 12 13 12 12 11
40 17 11 11
77
666
50
5
3322111
25
60 <1 <1 <1 <1 <1 <1 <1 <1
35 43 28 28 14 16 15 15 13
40 24 15 15 8 8 8 8 6
50
7
4422222
30
60 2<1<1<1<1<1<1<1
Table 13 Sound Pressure Levels for an RBS 2106 Against a Wall, with Heat Exchanger
Calculated Distance in Metres, Each Direction
Without Sound Hood With Sound Hood
Temp
Sound
Pressure
Level
dBA
Front Left Right Front Left Right
35 10 8 8
5
66
40
5
44333
50 1<1<1<1<1<1
15
60 <1 <1 <1 <1 <1 <1
35 20 16 16 10 10 10
40 11 8 8
555
50 3 2 2<1<1<1
20
60 <1 <1 <1 <1 <1 <1