Reference Manual Part 1
RBS 2106
Table 6 Maximum Power to Antenna for Various RBS 2106 Configurations
Configuration
Frequency
(MHz)
Nominal Output
Power per TRU
(dBm)/(W)
Maximum Power
into Antenna
(1)
(dBm)/(W)
900 45.2 / 33 47.2 / 523x2 no hybrid
1800 44 / 25 46 / 40
900 41.7 / 15 46.7 / 473x4 combined
1800 40.5 / 11 45.5 / 35
900 47.7 / 59 49.7 / 933x2 TCC
1800 46.5 / 45 48.5 / 71
900 42.7 / 19 52.5 / 1771x12 filter
combiner
1800 41.5 / 14 51.3 / 135
(1) Including power tolerance level (+2 dB) and transmission losses (-3 dB).
4.4 Materials
All Ericsson products fulfil legal, market, and Ericsson requirements regarding:
• Fire resistance of material, components, wires and cables
• Declaration of materials
• Use of restricted materials
• Recycling
Packaging Material
The packaging material is recyclable.
5 Hardware Units
A high level of availability is achieved using strict functional modularity in a
system of standardised Replaceable Units (RU). A failed RU can easily be
replaced by a new one.
14 (36)
E