Reference Manual Part 1

RBS 2106
Climatic Requirements
Table 3 Climatic Requirements
Description Temperature Relative Humidity
Normal Conditions
-33 C to +45 C
(1)
15 100%
Transport
-40 C to +70 C
5 100%
Storage
-25 C to +55 C
10 100%
Handling
-40 C to +70 C
5 100%
(1) Upper limit +40 C with the Heat Exchanger.
Acoustic Dispersion Heat Exchanger
The cabinet noise dispersion for an RBS 2106 with Heat Exchanger Climate
Unit is shown in the two figures below. The figures show the noise dispersion
generated by a free-standing cabinet, and by a cabinet mounted against a wall.
Note: The acoustic noise dispersion values for a free-standing cabinet and
a cabinet installed against a wall were tested according to the ISO
9614-2 standard. Deviations from these values can be experienced
due to the nature of materials in the environment where the cabinet
is installed. Objects near the cabinet can reflect or absorb sound and
thus affect acoustic dispersion.
8 (36)
E
N/LZT 720 0222 Uen R6A