Reference Manual Part 1
Hardware Reference Manual RBS 2106, RBS 2206, RBS 2207
Seismic Exposure
The complete equipped RBS shall be tested for seismic exposure. Deviations
shall be reported.
Safe function during seismic exposure. Deviations shall be reported.
Table 13 Seismic exposure limits for indoor operation
Test frequency range 1 - 35 Hz
Required Response
Spectrum
RRS
Shape of RRS as IEC fig. 3
Number of time scale
histories
1/ testing direction
Duration of time scale
histories
35 s
Number of testing directions
3
If necessary there are possibilities to equip the RBS with an optional Seismic
Exposure protection device.
3.8 Operation Outdoor -33 C – +40 C
This Environmental class corresponds in full to Operation Outdoor -33 C -
+45 C with the exception of the upper temperature limit.
3.9 Operation Outdoor -33 C – +45 C
The severity of the requirements is in conformity with: IEC 721-3-4 classes
4K2/4Z5/4Z7/4B1/4C2(4C3)/4S2/4M5. and ETS 300 019-1-4 Class 4.1.
"NON-WEATHERPROTECTED location", except for the temperature range
which is extended to +45 C.
This clause refers to the environment which an RBS for outdoor non-weather
protected location endures.
The figures below refer to the environment that surrounds the cabinet, and the
temperature is the shaded air temperature.
3.9.1 Climatic Conditions
The severity of these requirements is in conformity with: IEC 721-3-4 classes
4K2/4Z5/4Z7. and ETS 300 019-1-4 Class 4.1. In addition to this Ericsson
demands more rigorous values than stated by IEC and ETSI above.
19EN_LZT_720_0024 Uen R7A 2004-08-19