Reference Manual Part 1

RBS 2206
TMR 9202
The connectors used for this are:
PCM cables
+24 V DC cables
Blank panels for connectors to the OXU
9 External Alarms
The RBS 2206 supports a maximum of 16 external alarms. The external alarm
device can set the alarm using either an open or a closed condition.
The alarm device connected to the screw terminals should be isolated relay
contacts. A closed contact (logic zero) is required to be below 2 k
, and an open
contact (logic one) above 100 k
. The current through a closed 0 W contact is
1.2 mA. The voltage between terminals with an open contact is 24 V DC.
The external alarms are defined at the installation. They are defined by using
the OMT or from the BSC using the remote OMT.
Note: An installed DC/DC Converter is hard-coded to alarm input 16 in the
External Alarm Unit. Pin 16 is therefore unavailable.
Note: An installed Smoke detector is hard-coded to alarm input 2 and 3 in the
External Alarm unit. Pins 2 and 3 are therefore unavailable.
10 Standards, Regulations and Dependability
This section provides a brief overview of st
andards, type approval, and EMC.
10.1 Safety Standards
In accordance with the market requirements, the RBS 2206 complies with the
following product safety standards:
73/23/EEC Low voltage directive
IP 20 according to IEC/EN 60529
FCC rules, part 68
EN 60950 / IEC 60950
EN 60215 / IEC 60215
UL 1950 / CSA C22.2 No.950
26 (28)
E
N/LZT 720 0225 Uen R6A