Reference Manual Part 1
RBS 2206
Indicators Description
EPC bus fault Indicates the state of the EPC bus
Ext alarm One or more supervised external
alarms are active
Fault Fault detected and localised to the
RU
Local mode The RU is in local mode
Operational The RU is operational
Transmission OK Indicates state of transmission on
ports A – D
RF off RF not enabled
Buttons Description
dTRU reset Resets the dTRU
DXU reset Resets the DXU
Local/remote mode Changes RU mode to local or remote
7 Power System
The power system of the RBS 2206 depends on the choice of power supply
and may include a number of units outside the RBS.
The RBS 2206 can be connected either to AC mains supply voltage or to DC
supply voltage.
7.1 AC Mains Supply Voltage
AC mains supply voltage is connected to the cabinet using four AC cables.
If the power supply does not meet the AC power requirements, then filters
and stabilisers must be installed to protect the equipment and ensure proper
operation.
There are two ways to connect power to the base station. They are:
• Single phase, line to neutral
• Single phase, line to line
Note: When single phase line to line is used, each PSU requires two circuit
breakers or fuses.