Product Description Part 2

RBS 210 6 and RBS 2206 Radio Configurations
Table 27 Expansion using Hybrid Combine r
Original Configuration Exp ansion Configura tion
Re-
sult
SCC
Orig-
inal
SCC
Cab i-
net
Combi-
ner
Anten-
nas
TMA
Orig-
inal
SCC
Basic C on-
figuration
Antennas
RBS
205
HCOMB
& DPX
(2) ( 2) (2) No 3 x
G18dh_2.4
(2) (2) (2)
RBS
205
HCOMB (2) (2) (2 ) M 3 x
G18dht_2.4
(2) (2) (2)
(1) 3 x 6 can be accomplished with a partly-equipped expansion configuration. 1 x 8 can be
accomplished with one RBS 200/RBS 205 and a partly-equipped expansion configuration.
(2) When using TG-synchronization, only one RBS 200/RBS 205 can act as master. Therefore
the 3 x 4 configuration, which contains three separate RBSs, must be rebuilt to o ne single RBS;
that is, all t hree sectors of the RBS 200 must be connected to the same TMCB.
M = Mandatory
7.2 6-TRX RBS 2000 Macro Cabinets Expanded with 12-TRX Cabinet
Co-siting with Single TRU-Based RBS 2000 Usi ng Filter Combiner
Table 28 Expansion using Filter combiner
RBS 1 RBS 2
Result
SCC
Original
SCC
Basic Con-
figuration
Antennas
Original
SCC
Basic Con-
figuration
Antennas
1 x 18
(1)
1 x 6 D9d_2.6 (2) 1 x 12 F9de_ 2.12 (2)
D18d_2.6 (2) F18d_2.12 (2)
D18_2.6 (2) F18dt_2.12 (2)
1 x 24
(2)
1 x 12 D9d_2.12 (2) 1 x 12 F9de_2.12 (2)
D18d_2.12 (2) F18d_2.12 (2)
D18_2.12 (2) F18dt_2.12 (2)
(1) 1 x 8, 1 x 10, 1 x 12, 1 x 14 and 1 x 16 can be accomplished with a partly-equipped RBS 2.
(2)
53 (62)
EN/LZT 720 0318 Uen R5A