Manual Part 5

CXU-10
Figure 1 B lock Diagram of the CXU-10
4.1 Functions
The CXU has six different switches. B y setting the switches in different
posi tions, the CXU can be configured to connect radio signals from a specific
CDU to a specific RX input on a dTRU.
The CXU i s also connected to a CDU bus. By sending data through the CDU
bus, the switches can be set to fulfil the supported configurations.
The unit contains splitters for distribution of incoming RX signals to the switches
and in some cases directly to an output.
The R F cables betwe en the CDU and CXU, and the CXU and dTRU, are
supervised by t he CXU.
4 (6)
E
N/LZT 720 0240 Uen R2A