Manual Part 5

CD U-F
The Measurement Receiver (MR) and the Central Pro cessor Unit (CPU) contro l
the tuning of the filter cavities.
A small part of the output and refle cted power is distributed by the Measurement
Coupler Unit (MCU) to four outputs. The signals are then connected to the MR in
the same C DU-F, or the MR in another CDU-F, depending o n the configuration.
The MR measures the input signal to the filt er combiners and also the outgoing
signal to the anten na. These two signals are used in the Central Processing
Unit (CPU) to control the stepper motors, one for each filte r cavity. Moving p arts
in the filter cavity, tune the com biner to the correct frequency.
4.2 RX Part Description
The duplex filter filters out th e RX signal arriving to the antenna. This filtered
signal is amplified in a two-stage low-noise amp lifier and is then filtered in
a lowpass filter.
The CDU-F also has a n extra RX c hain for diver sity r eception. This extra RX
chain is similar to the duplex RX chain.
Distribution of RX signals is performed in the CXU.
5 Interf aces
The external interfaces of the CDU-F are listed in the table below.
Table 3 Interfaces on CDU-F
Interface Type of Connector
TX/RX, RX 7 16 female
RX1, RX2 QMA female
TX1 T X4 TNC female
Pf in1, PF in2, Pr in1, Pr in2 SMA fema le
Pf out1, Pf out2, Pr o
ut1, P r out2
SMA fema le
FC N female
CDU bus 15-pin male, D -sub
DC in 2-pin male Molex Mini-Fit
The CDU-F has the following indicators on the front panel.
5 (6)
EN/LZT 720 0237 Uen R3A