Manual Part 5

ACCU -01
P006805A
ACCU
Figure 1 ACCU Interfaces
The ACCU has the following external interfaces:
Termi nal block for incoming AC mains cables
Four connection points for outgoing cables to the PSUs
4.1 Signal and Power Interfaces
Input Data
The input data is shown in the table below.
Table 2 In put Data
Frequency 50 60 Hz
Voltage 120 250 AC nominal
External Fuses 4 pcs, max. 16 A
Cable Diameter
8.5 12.5 mm
Conductor Area
1.5 2.5 mm
2
Number of Conductors
4 x (L, N, PE), four cables
4 (6)
E
N/LZT 720 0229 Uen R2A