Manual Part 4
RBS 2206 Antenna Configurations
6.4 1x4 CDU-G without HCU and 1x8 CDU-G with HCU Configuration
The figure below shows the 1x4 CDU-G without Hybrid Combiner Unit (HCU)
and 1x8 CDU-G with HCU configuration.
P008233D
DX1
Cell
A
TX2
TMA TMA
DX2TX1
Optional Optional
Figure 1 8 1x 4 CDU-G without HCU and 1x8 CGU -G with HCU Configuration
Table 11 1x4 CDU-G
without HCU and 1x8 CDU -G with HCU Configuration
CDU
Cell
CDU
No.
Feeder
Label
CDU
Connector
Signal
ASU
Connector
CellA: DX1 TX/RX1 TX/RX A 11
CellA: TX1 TX/RX2 TX –
CellA: DX2 TX/RX1 TX/RX B 3
A
2
CellA: TX2 TX/RX2 TX –
17 (24)
EN/LZT 720 0320 Uen R3A