Manual Part 4

RBS 2206Antenna Configurations
6 CDU-G Configurations
Note: In the figures and tables that follow, only cabinets that are fully-equipped
are shown. Configurations consisting of part of the fully-equipped
cabinet can also be extracted from the following figures and tables.
See Figure 3 on page 4 and Figure 14 on page 13 for an illustration of each of
the column headers in the tables below.
6.1 3x2 CDU-G and 3x4 CDU-G Configuratio n
The figure below shows the 3x2 CDU-G and 3x4 CDU-G configuration.
Figure 15 3x2 C DU-G and 3x4 CDU-G Configur ation
Table 8 3x2 CD U-G and 3x4 CDU-G Co nfiguration
CDU
Cell
CDU
No.
Feeder
Label
CDU
Connector
Signal
ASU
Connector
CellA: DX1 TX/RX1 TX/RX A 1A 1
CellA: DX2 TX/RX2 TX/RX B 2
CellB: DX1 TX/RX1 TX/RX A 3B 2
CellB: DX2 TX/RX2 TX/RX B 4
CellC: D
X1
TX/RX1 TX/RX A 5C 3
CellC: DX2 TX/RX2 TX/RX B 6
14 (24)
E
N/LZT 720 0320 Uen R3A