RBS 2106Antenna Configurations
6.2 2x1 CDU-G Configuration
The figure below shows the 2x1 CDU-G configuration.
P011300A
TMA
Cell
C
TMA TMA TMA
Cell
B
TMA TMA
Cell
A
DX1
RXB
DX1
DX2
DX1
Optional Optional Optional Optional OptionalOptional
RXB
Figure 16 2x1 CDU -G Configuration
Table 9 2x1 CDU-G Configuration
CDU
Connector
Cell
CDU
No.
Feeder
Label
CDU
Con n.
Field
Signal
ASU
Connector
1 CellA: DX1 TX/RX1 A1 TX/RX A B1A
2 CellA: RXB TX/RX1 A3 RX B B3
1 CellB: DX1 TX/RX2 A2 TX/RX A B2B
2 CellB: RXB TX/RX2 A4 RX B B4
18 (28)
E
N/LZT 720 0319 Uen R3A