User Manual

Table Of Contents
RBS 2107
Table 6 Maximum Power to Antenna for Various RBS 2107 Configurations
Configuration
Frequency
(MHz)
Nominal Output
Power per TRU
(dBm)/(W)
Maximum Power
into Antenna
(1)
(dBm)/(W)
900 45.2 / 33 47.2 / 533×2 no hybrid
1800 44 / 25 46 / 40
900 41.7 / 15 43.7 / 233×2 combined
1800 40.5 / 11 42.5 / 18
900 47.7 / 59 46.7 / 473×1 TCC
1800 46.5 / 45 45.5 / 35
(1) Including power tolerance level (+2 dB) and transmission losses (-3 dB).
4.4 Materials
All Ericsson products fulfil legal, market, and Ericsson requirements regarding:
Fire resistance of material, components, wires and cables
Declaration of materials
Use of restricted materials
Recycling
Packaging Material
The packaging materials are recyclable.
5 Hardware Units
A high level of availability is achieved using strict functional modularity in a
system of standardised Replaceable Units (RU). A failed RU can easily be
replaced by a new one.
11 (28)
EN/LZT 720 0491 Uen R2A