Reference Manual

Radio Base Station RBS 2106
6 (30) EN/LZT 720 0222 R3A
Table 2 RBS 2106 colours
Colour Reference number Ericsson number
Grey RAL 7035 MZY 543 03/8119
Green NCS 8010-G 10Y MZY 543 03/685
3 Space requirements
Installation and maintenance require that the door can be opened at least 90°.
In practice this means that the space in front of the cabinet must be kept clear
for a distance of 1300 mm, see figure below. No free space is needed at the
back of the cabinet, but to ensure that the door can be opened easily there
must be at least 20 cm of free space to the left of the cabinet.
If the RBS is located next to another cabinet of the same depth, no adjacent
space is required. If the RBS is placed next to a wall, or any object protrudes
on the left side, then 175 mm clearance is required to the left of the cabinet.
Unit of measurment: mm
P008564B
r = 1300 mm
90
Figure 2 Door opening requirements
Note: All installation and maintenance work can be done with the door
opened 90°.
During service a tent can be placed over the cabinet to protect the equipment
from unsuitable weather conditions.