User's Manual

RBS 2308Micro RBS
4 Environment
This section provides an overview of the operating environment, environmental
impact, and materials used in the RBS 2308.
4.1 Operating Environment
The operational temperature limits of the RBS 2308 depend upon the power
supply and whether or not the fan is used, see tables below.
Table 3 Start-up and operational requirements using AC power
RBS 2308 Variant
Temperature range Relative Humidity
Without optional fan
33 Cto+45C
15 100%
With optional fan
33 Cto+55C
15 100%
Table 4 Start-up and operational requirements using DC power
RBS 2308 Variant
Temperature range Relative Humidity
Start-up
0 Cto+45C
15 100%
Operational, without
optional fan
15 Cto+45C
15 100%
Operational, with
optional fan
15 Cto+55C
15 100%
Temperature limits for transport, storage and handling of the RBS 2308 are
given in the table below.
Table 5 Transport, storage and handling climatic requirements
Condition
Temperature range Relative Humidity
Transport
40 Cto+70C
5 100%
Storage
25 Cto+55C
10 100%
Handling
40 Cto+70C
5 100%
8 (30)
EN/LZT 720 0327/3 Uen R1A