- 1 Introduction
- 2 Product Overview
- 3 Dimensions
- Size and Weight
- Surface and Colour
- 4 Space Requirements
- Footprint
- 5 Environment
- 6 Hardware Units
- 7 Interfaces
- 7.1 External Connections
- Connections on DF
- Overvoltage Protection Modules in the RBS 2106i and RBS 2106 V3
- Overvoltage Arrestors for External Alarms in the RBS 2106
- Antenna Connections
- Other External Connections
- External Connections to TM
- Transport Network to TM
- 7.2 Test Interface
- 7.3 Operator Interface
- Indicators
- Buttons
- 8 Power System
- 8.1 Power Supply
- AC Mains Supply Voltage
- External Earth Fault Circuit Breakers
- Mains Fuses
- 8.2 Battery Backup
- Internal Battery Backup
- External Battery Backup
- 8.3 Output Power to TM
- 8.4 Power Consumption
- 9 Transmission
- Optional Transmission Equipment
- 10 External Alarms
- 11 Standards, Regulations and Dependability
PRELIMINARY
RBS Product Description
tolerances and transmission loss) per TRU, for RBS 2106 at 900 MHz and
1800 MHz, are given in Table 19.
Table 19 Maximum Power to Antenna for Various RBS 2106 Configurations
Configuration
Frequency
(MHz)
Nominal Output
Power per TRU
(dBm)/(W)
Maximum
Power to
Antenna
(1)
(dBm)/(W)
900
45.2 / 33 47.2 / 523×2 no hybrid
1800
44 / 25 46 / 40
900
41.7 / 15 46.7 / 473×4 combined
1800
40.5 / 11 45.5 / 35
900
47.7 / 59 49.7 / 933×2 TCC
1800
46.5 / 45 48.5 / 71
900
42.7 / 19 52.5 / 177
1×12 filter
combiner
1800
41.5 / 14 51.3 / 135
(1) Including power tolerance level (+2 dB) and transmission losses (
0
3 dB).
5.4 Materials
All Ericsson products fulfil legal, market, and Ericsson requirements regarding
the following:
• Fire resistance of materials, components, wires, and cables
• Declaration of materials
• Use of restricted materials
• Recycling
Packaging
The packaging is recyclable.
22
129/1551-LZA 701 0001 Uen PF1 | 2010-10-08