User Manual
Table Of Contents
- toc
- 1 Introduction
- 2 Product Overview
- 3 Dimensions
- Weight
- Colour
- 4 Space Requirements
- Space above the RBS Cabinet
- Layout for RBS Cabinets
- Earthquake Requirements
- Footprint
- 5 Environment
- 6 Hardware Units
- 6.1 RBS 2206 Standard Hardware Units
- ACCU-01
- CDU
- CXU-10
- DCCU-01
- dTRU
- DXU-21
- FCU
- IDM-01
- PSU
- DC Filter-01
- 6.2 RBS 2206 V2 Standard Hardware Units
- ACCU-11
- CDU
- CXU-10
- DCCU-11
- DCCU-13
- dTRU
- DXU-23
- IDM-11
- PSU
- 6.3 Optional Hardware Units
- ASU-01
- Bias Injector
- BBS
- ddTMA
- DXX
- DF
- ESB
- HCU
- 19-inch Space for Optional Equipment
- OXU
- Splitter
- TMA-CM-01
- TMA-CM-02
- 7 Interfaces
- 8 Power System
- 9 Transmission
- Overvoltage Protection Modules
- Optional Transmission Equipment
- 10 External Alarms
- 11 Standards, Regulations and Dependability
Power System
Characteristic
Description
Voltage 90–275 V AC
(1)
Frequency 45–65 Hz
Maximum inrush current 30 A (1–30 ms)
Maximum AC power, RBS 2206 4 × 1.4 kW
Maximum AC power, RBS 2206 V2 3 × 1.7 kW
Non-destructive range 0–275 V AC
(1) Install external filter and stabilizer if the requirement is not met.
RBS 2206 AC Fuses
Table 10 Fuse Specifications
Minimum for Safe
Function
Recommended for
Maximum Selectivity
Maximum Allowed
Fuse Rating
4 × 10 A
(1)
4×16A 4×20A
(1) For 200–250 V range only.
RBS 2206 V2 AC Fuses
Table 11 Fuse Specifications
120–127 V AC
(Nominal)
200–250 V AC
(Nominal)
Maximum Allowed
Fuse Rating
3 × 16 A 3 × 10 A 3 × 16 A
External Earth Fault Circuit Breakers
If external earth fault (ground fault) circuit breakers are used, then the
recommended minimum trip value is 100 mA.
8.2 +24 V DC Power
Table 12 +24 V DC Power Requirements
Characteristic
Description
Nominal +24 V DC
Default +27.2 V DC
Range +20.5 to +29.0 V DC
Non-destructive range +0 to +32 V DC
Inrush current Max. 500 A (0.1–10 ms)
2719/1551-LZA 701 0001 Uen PG1 | 2010-10-08