Reference Manual
RBS 2206 Radio Base Station
EN/LZT 720 0225 R3A 11 (24)
5 Hardware Units
A high level of availability is achieved using strict functional modularity with a
system of standardised units. A failed unit can easily be replaced by a new
one. It is possible to add up to three new units in the PSU/DXU magazine.
The RBS 2206 cabinet contains the radio equipment, power supply and the
climate equipment (fans). All required transmission equipment and battery
back-up must be housed outside the cabinet.
Outside equipment is listed under optional units. Not all HW units are covered
in this section, only those directly related to RBS.
5.1 Standard Hardware Units
This section briefly describes the standard hardware units required for
functionality, irrespective of configuration or frequency.
P008165A
PSU
Base frame
Fans
FCU
ACCU or
DCCU
DC filter
Connection
field
IDM
CDU
DXU
dTRU
CXU
Connection
field
OXU
Figure 5 Standard hardware units
ACCU – AC Connection Unit
The ACCU handles distribution and connection/disconnection of the incoming
AC power supply voltages to the PSUs. Connection/disconnection is
performed by the main switch. The unit also contains filter equipment.
Number of units: 1