Reference Manual
RBS 2106 Radio Base Station
EN/LZT 720 0222 R3A 27 (30)
7.4 Power Consumption
Table 14 Power consumption
Climate system
Power consumption,
input voltage >200 V
AC
Power consumption,
input voltage < 120 V
AC
Heater plus forced-air
cooling only
5948 W 6049 W
Heater plus
refrigerated cooling
6588 W 6049 W
8 Transmission
The RBS 2106 supports two transmission standards:
• T1 1.5 Mbit/s, 100 Ω, with internal synchronisation
• E1 2 Mbit/s, 75 Ω, with PCM synchronisation
• E1 2 Mbit/s, 120 Ω, with PCM synchronisation
9 External Alarms
The RBS 2106 supports a maximum of 16 external alarms. The external alarm
device can set the alarm by either an open or a closed condition.
The alarm device connected to the screw terminals should be isolated relay
contacts. A closed contact (logic zero) is required to be below 2 kΩ, and an
open contact (logic one) above 100 kΩ. The current through a closed 0 Ω
contact is 1.2 mA. The voltage between terminals with an open contact is 24 V
DC.
The external alarms are defined at the installation. They are defined by using
the Operation and Maintenance Terminal (OMT) or from the BSC using the
remote OMT.
10 Standards, Regulations and Dependability
In this section a brief overview over standards, type approval and
electromagnetic compatibility are stated.
10.1 Safety Standards
In accordance to the market requirements, the RBS 2106 complies with the
following product safety standards:
• 73/23/EEC Low voltage directive