Reference Manual
EMC Capabilities
Table 30 Surge test 1.2/50 pulses
Limit standard EN 61000-4-5
Test level 2 kV common mode between line and cabinet ground reference
1 kV differential mode between line and line
Performance Criteria B for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
Table 31 Surge test 10/700 pulses
Limit standard EN 61000-4-5
Test level 1 kV common mode between line and cabinet ground reference
1 kV differential mode between line and line
Performance Criteria B for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
Table 32 Power induction test
Basic standard ITU-T K.20
Test level 600 V(rms) common mode
Performance Criteria A(K.20)
Table 33 RF common mode test
Limit standard ETS 300 342-2
Test level 10 V(rms)
Performance Criteria A for a complete system
Criteria CT for transmitter units
Criteria CR for receiver units
4.3.7 Radiated Immunity of Enclosure Port
Table 34 Immunity of continuous electric fields
Basic standard IEC 801-3
Test level 10 V/m
Performance Criteria A
Limit standard ETS 300 342-2
Test level 10 V/m, 80 MHz - 1 GHz
Frequency range 30 V/m, 1 GHz-20 GHz
Performance Criteria A for a complete system
EN/LZT 720 0024 R2A
2002-11-01
33 (34)
© Ericsson Radio Systems AB
— All Rights Reserved —