User Manual
Table Of Contents
- toc
- RBS Product Description
- 1 Introduction
- 2 Product Overview
- 3 Dimensions
- 4 Space Requirements
- 5 Environment
- 6 Hardware Units
- 7 Interfaces
- 7.1 External Connections
- 7.2 Test Interface
- 7.3 Operator Interface
- Figure 18 Power System
- 8.1 Power Supply
- 8.2 Battery Backup
- 8.3 Output Power to TM
- 8.4 Power Consumption
- 9 Transmission
- 10 External Alarms
- 11 Standards, Regulations and Dependability
- RBS Product Description
- tables
- Table 1 RBS Weights with Combined Climate Unit
- Table 2 RBS Weights with Heat Exchanger Climate Unit
- Table 3 RBS 2106 Colours
- Table 4 RBS 2106 Climatic Requirements
- Table 5 RBS 2106i and RBS 2106 V3 Climatic Requirements
- Table 6 Sound Pressure Level, Bystander Position without Sound H
- Table 7 Sound Pressure Level, Bystander Position with Sound Hood
- Table 8 Sound Pressure Levels for a Free Standing RBS with Combi
- Table 9 Sound Pressure Levels for an RBS against a Wall, with Co
- Table 10 Sound Pressure Level, Bystander Position without Sound
- Table 11 Sound Pressure Level, Bystander Position with Sound Hoo
- Table 12 Sound Pressure Levels for a Free Standing RBS€2106 with
- Table 13 Sound Pressure Levels for an RBS€2106 Against a Wall, w
- Table 14 Sound Pressure Level, Bystander Position without Sound
- Table 15 Sound Pressure Levels for a Free Standing RBS 2106i or
- Table 16 Sound Pressure Levels for an RBS 2106i or RBS€2106€V3 w
- Table 17 Compliance Boundary Dimensions for the General Public (
- Table 18 Characteristics of Typical Antenna
- Table 19 Maximum Power to Antenna for Various RBS€2106 Configura
- Table 20 Maximum Dimensions
- Table 21 Power Distribution for the TM Space
- Table 22 Connection Field Inlets in RBS 2106i and RBS 2106 V3
- Table 23 OVP Module Capacity
- Table 24 Overvoltage Arrestors
- Table 25 Antenna Connections
- Table 26 External Connections
- Table 27 Optical Indicators
- Table 28 Switches and Circuit Breakers
- Table 29 Power Parameters
- Table 30 Mains Fuses Recommendation
- Table 31 Output Power
- Table 32 Maximum Power Consumption during Battery Charging
Ericsson Internal
DESCRIPTION 48 ( 50 )
/ XSNSIXI 129/1551-LZA 701 0001 Uen
CBC/ XRX/M ( Kai Lian) 2011-05-05 F
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
11 Standards, Regulations and Dependability
This section provides a brief overview of standards, type approval, and EMC.
11.1 Safety Standards
In accordance with the market requirements, the RBS 2106 complies with the
following product safety standards:
• 73/23/EEC Low voltage directive
• IP 55 according to IEC 60529
• EN 60950 / IEC 60950
• EN 60215 / IEC 60215
• UL 1950
• CSA 22.2 No. 950
11.2 Other Standards and Regulations
Marking
The product is marked with symbols to indicate compliance with product safety
standards.
Type Approval Standards
The RBS complies with the European Community and the North America
market requirements regarding radio performance. The product has the CE
and FCC symbols to indicate compliance with the legal requirements of the
respective region.
EMC
The RBS complies with the European Community and the North America
market requirements regarding EMC. The product has the CE and FCC signs
to indicate compliance with the legal requirements of the respective region.
Dependability
The RBS 2106 is designed for a technical lifetime of 25 years (24-hour
operation). The following preventive maintenance conditions must be fulfilled to
guarantee the availability of the RBS: