DESCRIPTION 40 ( 50 )
/ XSNSIXI 129/1551-LZA 701 0001 Uen
CBC/ XRX/M ( Kai Lian) 2011-05-05 F
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
P017212C
CDU-K
TMA-CM
connection plate
CF cover
Figure 17 RBS 2106i and RBS 2106 V3 Antenna Connections with CDU-K
Other External Connections
Table 26 External Connections
Connection
Location
Connection To Type Connector
AC connection box AC Mains connections Screw terminal for wires
4 16 mm
ACCU AC Service outlet IEC 83:1975 standard C
2b (Sweden, Germany
and others)
IEC 83:1975 standard
B2, same as BS
1363:1984 standard
13A (UK)
IEC 83:1975 standard
A5-15 (USA)
Reference earth Earthing connection M8 screw, 50 mm
2
stranded
copper wire
External Connections to TM
Optical fibre and Mini-Link radio cables are connected to the TM through
connection field 3. Twisted pair cables connect to the TM through the OVP.