Table Of Contents
- toc
- RBS Product Description
- 1 Introduction
- 2 Product Overview
- 3 Dimensions
- 4 Space Requirements
- 5 Environment
- 6 Hardware Units
- 7 Interfaces
- 7.1 External Connections
- 7.2 Test Interface
- 7.3 Operator Interface
- Figure 18 Power System
- 8.1 Power Supply
- 8.2 Battery Backup
- 8.3 Output Power to TM
- 8.4 Power Consumption
- 9 Transmission
- 10 External Alarms
- 11 Standards, Regulations and Dependability
- RBS Product Description
- tables
- Table 1 RBS Weights with Combined Climate Unit
- Table 2 RBS Weights with Heat Exchanger Climate Unit
- Table 3 RBS 2106 Colours
- Table 4 RBS 2106 Climatic Requirements
- Table 5 RBS 2106i and RBS 2106 V3 Climatic Requirements
- Table 6 Sound Pressure Level, Bystander Position without Sound H
- Table 7 Sound Pressure Level, Bystander Position with Sound Hood
- Table 8 Sound Pressure Levels for a Free Standing RBS with Combi
- Table 9 Sound Pressure Levels for an RBS against a Wall, with Co
- Table 10 Sound Pressure Level, Bystander Position without Sound
- Table 11 Sound Pressure Level, Bystander Position with Sound Hoo
- Table 12 Sound Pressure Levels for a Free Standing RBS€2106 with
- Table 13 Sound Pressure Levels for an RBS€2106 Against a Wall, w
- Table 14 Sound Pressure Level, Bystander Position without Sound
- Table 15 Sound Pressure Levels for a Free Standing RBS 2106i or
- Table 16 Sound Pressure Levels for an RBS 2106i or RBS€2106€V3 w
- Table 17 Compliance Boundary Dimensions for the General Public (
- Table 18 Characteristics of Typical Antenna
- Table 19 Maximum Power to Antenna for Various RBS€2106 Configura
- Table 20 Maximum Dimensions
- Table 21 Power Distribution for the TM Space
- Table 22 Connection Field Inlets in RBS 2106i and RBS 2106 V3
- Table 23 OVP Module Capacity
- Table 24 Overvoltage Arrestors
- Table 25 Antenna Connections
- Table 26 External Connections
- Table 27 Optical Indicators
- Table 28 Switches and Circuit Breakers
- Table 29 Power Parameters
- Table 30 Mains Fuses Recommendation
- Table 31 Output Power
- Table 32 Maximum Power Consumption during Battery Charging
Ericsson Internal
DESCRIPTION 33 ( 50 )
/ XSNSIXI 129/1551-LZA 701 0001 Uen
CBC/ XRX/M ( Kai Lian) 2011-05-05 F
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
for the RBS. It is the responsibility of the owner/operator to obtain the type
approval. To ensure that the RBS function is not violated, the following is
recommended:
• Any transmission equipment installed in the TM must fulfil the requirements
in the Generic EMC standards IEC61000-6-3 and IEC61000-6-2
• All in/out interfaces (signal and power), which pass the cabinet border
between two different EMC zones, must be sufficiently EMC-protected
(transient protection, filtering)
• Shielded cables are recommended for connections between transmission
equipment and the cabinet connection field, and between transmission
equipment and the DXU or DXX.
The recommended installation is shown in the figure below.
RBS
cabinet
TM
Transmission
equipment
DXU
(DXX)
Lightning
Protection
and
RF filter
P012580A
Figure 12 Recommended TM Installation
The maximum dimensions for the TM are shown in the table below.
Table 20 Maximum Dimensions
Dimension
Size
Panel width
485 mm
Height
445 mm
Depth behind mounting rails
267 mm
Depth behind mounting rails
280 mm
Space in front of mounting rails
(1)
65 mm
(1) For cables and connectors.