User Manual
Table Of Contents
- toc
- RBS Product Description
- 1 Introduction
- 2 Product Overview
- 3 Dimensions
- 4 Space Requirements
- 5 Environment
- 6 Hardware Units
- 7 Interfaces
- 7.1 External Connections
- 7.2 Test Interface
- 7.3 Operator Interface
- Figure 18 Power System
- 8.1 Power Supply
- 8.2 Battery Backup
- 8.3 Output Power to TM
- 8.4 Power Consumption
- 9 Transmission
- 10 External Alarms
- 11 Standards, Regulations and Dependability
- RBS Product Description
- tables
- Table 1 RBS Weights with Combined Climate Unit
- Table 2 RBS Weights with Heat Exchanger Climate Unit
- Table 3 RBS 2106 Colours
- Table 4 RBS 2106 Climatic Requirements
- Table 5 RBS 2106i and RBS 2106 V3 Climatic Requirements
- Table 6 Sound Pressure Level, Bystander Position without Sound H
- Table 7 Sound Pressure Level, Bystander Position with Sound Hood
- Table 8 Sound Pressure Levels for a Free Standing RBS with Combi
- Table 9 Sound Pressure Levels for an RBS against a Wall, with Co
- Table 10 Sound Pressure Level, Bystander Position without Sound
- Table 11 Sound Pressure Level, Bystander Position with Sound Hoo
- Table 12 Sound Pressure Levels for a Free Standing RBS€2106 with
- Table 13 Sound Pressure Levels for an RBS€2106 Against a Wall, w
- Table 14 Sound Pressure Level, Bystander Position without Sound
- Table 15 Sound Pressure Levels for a Free Standing RBS 2106i or
- Table 16 Sound Pressure Levels for an RBS 2106i or RBS€2106€V3 w
- Table 17 Compliance Boundary Dimensions for the General Public (
- Table 18 Characteristics of Typical Antenna
- Table 19 Maximum Power to Antenna for Various RBS€2106 Configura
- Table 20 Maximum Dimensions
- Table 21 Power Distribution for the TM Space
- Table 22 Connection Field Inlets in RBS 2106i and RBS 2106 V3
- Table 23 OVP Module Capacity
- Table 24 Overvoltage Arrestors
- Table 25 Antenna Connections
- Table 26 External Connections
- Table 27 Optical Indicators
- Table 28 Switches and Circuit Breakers
- Table 29 Power Parameters
- Table 30 Mains Fuses Recommendation
- Table 31 Output Power
- Table 32 Maximum Power Consumption during Battery Charging
Ericsson Internal
DESCRIPTION 22 ( 50 )
/ XSNSIXI 129/1551-LZA 701 0001 Uen
CBC/ XRX/M ( Kai Lian) 2011-05-05 F
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
Ericsson has performed a free-space near-field RF exposure assessment of
typical configurations of the RBS 2106 with a recommended antenna. The
resulting dimensions, in metres, for a compliance boundary for both public and
occupational exposure, are shown in Table 17.
The compliance boundary is defined as a cylinder around the antenna, see
figure below. The antenna is not located at the centre of the cylinder. Instead
it is located almost at the edge, facing towards the center of the cylinder.
The distance between the antenna’s rear and the edge of the cylinder is the
so-called distance behind antenna. The height of the cylinder is the antenna
height plus equal distances above and below the antenna. The cylinder shape
overestimates the compliance distances right beside the antenna.
Figure 8 Compliance Boundary Cylinder
Table 17 Compliance Boundary Dimensions for the General Public (GP) and
Occupational (O) Exposure for Typical Configurations
Dimensions of Cylindrical Compliance
Boundary in (m)
Diametre Height Distance
Behind
Antenna
Configuration
Frequency
(MHz) GP O GP O GP O
900 6 3 1.7 1.5 0.1 0.1
3×2 no hybrid
1800
5
1 1.6 1.4 0.1 0.05
900 6 3 1.6 1.5 0.1 0.1
3×4 combined
1800
5
1 1.6 1.4 0.1 0.05
900 8 4 1.9 1.6 0.1 0.1
3×2 TCC
1800
7
2 1.6 1.5 0.1 0.1