User Manual
Table Of Contents
- toc
- RBS Product Description
- 1 Introduction
- 2 Product Overview
- 3 Dimensions
- 4 Space Requirements
- 5 Environment
- 6 Hardware Units
- 7 Interfaces
- 7.1 External Connections
- 7.2 Test Interface
- 7.3 Operator Interface
- Figure 18 Power System
- 8.1 Power Supply
- 8.2 Battery Backup
- 8.3 Output Power to TM
- 8.4 Power Consumption
- 9 Transmission
- 10 External Alarms
- 11 Standards, Regulations and Dependability
- RBS Product Description
- tables
- Table 1 RBS Weights with Combined Climate Unit
- Table 2 RBS Weights with Heat Exchanger Climate Unit
- Table 3 RBS 2106 Colours
- Table 4 RBS 2106 Climatic Requirements
- Table 5 RBS 2106i and RBS 2106 V3 Climatic Requirements
- Table 6 Sound Pressure Level, Bystander Position without Sound H
- Table 7 Sound Pressure Level, Bystander Position with Sound Hood
- Table 8 Sound Pressure Levels for a Free Standing RBS with Combi
- Table 9 Sound Pressure Levels for an RBS against a Wall, with Co
- Table 10 Sound Pressure Level, Bystander Position without Sound
- Table 11 Sound Pressure Level, Bystander Position with Sound Hoo
- Table 12 Sound Pressure Levels for a Free Standing RBS€2106 with
- Table 13 Sound Pressure Levels for an RBS€2106 Against a Wall, w
- Table 14 Sound Pressure Level, Bystander Position without Sound
- Table 15 Sound Pressure Levels for a Free Standing RBS 2106i or
- Table 16 Sound Pressure Levels for an RBS 2106i or RBS€2106€V3 w
- Table 17 Compliance Boundary Dimensions for the General Public (
- Table 18 Characteristics of Typical Antenna
- Table 19 Maximum Power to Antenna for Various RBS€2106 Configura
- Table 20 Maximum Dimensions
- Table 21 Power Distribution for the TM Space
- Table 22 Connection Field Inlets in RBS 2106i and RBS 2106 V3
- Table 23 OVP Module Capacity
- Table 24 Overvoltage Arrestors
- Table 25 Antenna Connections
- Table 26 External Connections
- Table 27 Optical Indicators
- Table 28 Switches and Circuit Breakers
- Table 29 Power Parameters
- Table 30 Mains Fuses Recommendation
- Table 31 Output Power
- Table 32 Maximum Power Consumption during Battery Charging
Ericsson Internal
DESCRIPTION 21 ( 50 )
/ XSNSIXI 129/1551-LZA 701 0001 Uen
CBC/ XRX/M ( Kai Lian) 2011-05-05 F
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
Table 16 Sound Pressure Levels for an RBS 2106i or RBS 2106 V3 with
Heat Exchanger, against a Wall
Temp
Calculated Distance in Metres,
Each Direction
(C
)
Sound
Pressure
Level,
dB(A)
Front Left Right
35644
40322
50 <1 <1 <1
15
60 <1 <1 <1
35644
40322
50 <1 <1 <1
20
60 <1 <1 <1
35 6 6
7
40333
50 <1 <1 <1
25
60 <1 <1 <1
35 18 13 13
40 10
77
50322
30
60 <1 <1 <1
35 36 26 26
40 20 14 14
50644
45
60 2 <1 <1
5.3 Compliance Distances for Electromagnetic Exposure
The compliance distance is the minimum separation that must be kept between
the antenna and a person to ensure that the ICNIRP Radio Frequency (RF)
exposure limits are not exceeded.
Note: ICNIRP, "Guidelines for limiting exposure to time-varying electric,
magnetic, and electromagnetic fields (up to 300 GHz)", International
Commission on Non-Ionizing Radiation Protection, Health Physics,
vol. 74, no. 4, 1998.