DESCRIPTION 13 ( 50 )
/ XSNSIXI 129/1551-LZA 701 0001 Uen
CBC/ XRX/M ( Kai Lian) 2011-05-05 F
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
5 Environment
The RBS 2106 is designed to operate within the limits stated for climatic
requirements listed in the table below, and to withstand ground vibrations as
stated below.
5.1 Operating Environment
Climatic Requirements
The operating environment and climatic specifications are shown in the tables
below.
Table 4 RBS 2106 Climatic Requirements
Description Temperature Relative Humidity
33
C to +45
C
(1)
Normal Conditions
33
C to +40
C
(2)
15 100%
Transport
40
C to +70
C
5 100%
Storage
25
C to +55
C
10 100%
Handling
40
C to +70
C
5 100%
(1) Temperature range valid if combined climate unit is used.
(2) Temperature range valid if heat exchanger climate unit is used.
Table 5 RBS 2106i and RBS 2106 V3 Climatic Requirements
Description Temperature Relative Humidity
Normal Conditions
33
C to +45
C
15 100%
Transport
40
C to +70
C
5 100%
Storage
25
C to +55
C
10 100%
Handling
40
C to +70
C
5 100%
Ground Vibrations
The RBS 2106 is designed to satisfy earthquake protection according to
IEC 68-2-57.
Levelling
To ensure that the cabinet is level, the floor must be level to within ±3 mm/2000
mm and the floor gradient must be within ±0.1
.
5.2 Environmental Impact
This section describes the effects that the cabinet has on the environment.