2/EN/LZT 720 0327 P1D 5 (22)
3 Space requirements
For installation and maintenance, and proper cooling during operation, the
space in front of the cabinet must be kept clear for a distance of 1000 mm,
and there must be at least 500 mm of free space on the right side and 250 mm
on the left. 300 mm free space is required above the cabinet, see figure below.
No free space is needed at the back of the cabinet.
The distance between the cabinet and the nearest obstruction (floor, filing
cabinet, another RBS, and so on) must be at least 500 mm.
P010123A
Unit of measurement: mm
RBS
250
500
300
1000
500
500
RBS
Figure 2 Space requirements
Mounting Base Holing Pattern
The mounting base of the RBS 2308 has the same holing pattern as that of
the RBS 2302.