User's Manual

RBS 2308Micro RBS
Table 25 Power consumption, basic cabinet
Operational condition
Power
consumption, AC
supply
Power
consumption, DC
supply
Norma
l operation (no heating)
360 VA 320 VA
Start-up of heating 3200 VA n/a
(1)
Continual heating 1000 VA n/a
(1) Heater is fed by AC power. No heating with DC power supply.
Power can also be supplied by the RBS 2308 to various external equipment,
for example an LMU. The additional power consumed in supplying external
equipment is given in the table below.
Table 26 Additional power consumption for various options
Option Additional Power Consumption
Optional fan unit 25 VA
External MINI-LINK 38 VA
Exter
nal LMU
52 VA
26 (30)
EN/LZT 720 0327/3 Uen R1A