9.3.9 SO CF RU:40/ Antenna
This section describes how to localise an SO CF RU:40/ Antenna fault.
Related RU
The RU listed below has higher priority than the RU described in this section. If
it is present, then go to the related section before handling this RU.
• If ‘‘SO CF RU:34/ IDB’’ appears in the OMT, then proceed with Section
9.3.8 SO CF RU:34/ IDB on page 169
Displaying Fault Information
Display fault information according to Section 9.3.1 Reading Fault Status on
page 159.
Perform the following actions step-by-step until the fault ceases:
Checking IDB Parameters
1. Check that the following values are correctly defined in the IDB:
• RX feeder loss
• TMA gain
Note: TMA loss = –TMA gain
Reading ARAE Alarm Status
Note: This step is only valid if ‘‘SO CF EC2:13/ Auxiliary equipment fault’’
appears in the OMT.
2. In the Configuration menu, select Read IDB and click Yes.
3. In the Maintenance menu, select Monitor.
4. Select Alarm Inlets and click Run.
5. Check that the ARAE fault is correctly defined in the IDB.
6. Check the cable to the equipment supervised by the ARAE alarm.
7. Replace the faulty equipment supervised by that alarm.
Checking RX Diversity
8. Ensure that the cell is configured, in the BSC, with the correct diversity
(RXD).
9. Confirm that radio cables are connected to the correct RRUs and antennas.