6. Release the trigger on the alarm and check that the alarm disappears
from the OMT.
7. Repeat steps 5 to 7 for all defined external alarms.
8. Close the RBS Event Monitor window when finished.
7.9 Performing Concluding Routines
This section describes the actions to take before leaving the site and provides a
site checklist. It also contains a test record.
7.9.1 Saving IDB
In case it is necessary to re-install the IDB, the IDB parameters must be saved
on the PC.
1. On the Configuration menu, click Save IDB.
2. Give the IDB file an RBS-specific name and save the IDB on the PC.
7.9.2 Checking RRU and IXU Indicators
1. Ensure that all lids are closed and fastened with screws.
2. Set the RRU and IXU in remote mode by pressing the Local/Remote
button.
3. Check that the RRU and IXU indicators have the status shown in the
applicable table below:
• Table 43 on page 139 shows the approved status of the RRU and IXU
indicators when the RBS is in remote mode but not connected to the BSC.
• Table 44 on page 139 shows the approved status of the RRU and IXU
indicators when the RBS is in remote mode, fully operational, and
connected to the BSC.