For supplementary information about RU maps, see:
Fault List Micro EN/LZT 720 0466
9.3.1 Reading Fault Status
This section describes how to read the fault status, using the OMT. If any fault
indicator on the RBS is on, then the fault status must be read.
Connect the OMT
1. Remove the lid from the OMT port on the IXU.
2. Connect the OMT cable from the PC serial port 1 to the OMT port on the
right-hand side of the IXU. If an extended OMT cable is connected to the
OMT port, then connect the OMT cable to the end of the extended OMT
cable.
3. Start the OMT
P010276B
Local/Remote
IXU temp.
AC power on
DC power on
Tra nsmission OK
Por t A
Por t B
Por t C
Por t D
OMT Cable
Figure 75 Connecting OMT to IXU
Reading the IDB
4. In the RBS 2000 menu, select Connect to logically connect the OMT to
the RBS.
5. In the Configuration menu, select Read IDB
6. On the Maintenance menu, click Monitor to open the Monitor window.
See figure below.