Note: The alarms must be individually identifiable in the OMT. There must
be no doubt which alarm was indicated. The alarm message must
be unique for each alarm.
1. On the Maintenance menu, click Monitor to open the Monitor window.
See figure below.
P010475A
Figure 67 Testing External Alarms
2. In the Available monitors box, select ‘‘External Alarm Status’’ and click to
add ‘‘Alarm Inlets’’ in the Monitors to start box.
3. Click Start monitor.
4. Trigger the desired alarm by either shorting or breaking it.
Note: Test the alarms in numerical order, and always start with alarm 1.
5. Check that the appropriate alarm appears in the RBS Event Monitor window.