User's Manual Part 3
RBS 2109 User’s Guide
7.
Enter Pass/Fail in the test record, see Section 8.4.2 Filling in the Test
Record on page 152.
8.1.2 Transmission Test on T1
This section describes how to test transmission, when the T1 transmission
interface is used.
Note: Transmission test on T1 can also be performed in the same way as E1,
according to Section 8.1.1 on page 144.
1. Request that the BSC operator uses CSU functions.
2. Configure the RBS for CSU, using OMT, and restart the RBS.
For more information regarding CSU ANSI, see:
BSS R11 Software Reference
Manual
EN/LZT 720 0047
1. Wait for the BSC to check the Digital Path on the active RBLT.
2. Deactivate CSU functions in the RBS, using OMT and restart the RBS.
3. Wait for the BSC operator to check that the Abis Paths are correctly defined
and that the Digital Path between the BSC and the RBS works properly.
4. Enter Pass/Fail in the test record, see Section 8.4.2 Filling in the Test
Record on page 152.
8.2 Bringing the RBS into Service
This section describes how to bring the RBS into service.
Note: The BSC operator can bring the MOs into service and deblock them
even when the RBS is in remote mode. (The RBS then responds
directly to the BSC operator.)
1. Set the RBS in local mode by pressing the Local/remote button on the IXU.
2. Wait until the Local indicator has a steady yellow light, indicating that the
RBS is in Local Mode.
3. Wait for the BSC operator to bring the MOs on each TRX into service
logically and deblock them.
4. Press the Local/Remote button on the IXU. The Local indicator will start
flashing.
1
46
E
N/LZT 720 0090 Uen R1A 2004-09-17