User Manual
Table Of Contents
- Contents
- 1 Introduction
- 2 Product Safety Requirements RBS 2000
- 3 Environmental Capabilities
- 3.1 Scope
- 3.2 Terminology
- 3.3 References
- 3.4 Transport -40 C – +70 C
- 3.5 Storage -25 C – +55 C
- 3.6 Handling -40 C – +70 C
- 3.7 Operation Indoor +5 C – +40 C
- 3.8 Operation Outdoor -33 C – +40 C
- 3.9 Operation Outdoor -33 C – +45 C
- 3.10 Operation Outdoor -33 C – +55 C
- 3.11 Operation Mast-Mounted Equipment -33 C – +45 C
- 3.12 Operation Mast-Mounted Equipment -40 C – +55 C
- 4 Climate Protection
- 5 EMC Capabilities
- RBS 2101, Product Description
- RBS 2102, Product Description
- RBS 2103, Product Description
- RBS 2202, Product Description
- RBS 2101, 2102, 2103 & 2202 Radio Configurations
- RBS 2202 Antenna Configurations
- ACCU Description
- BFU Description
- CDU-A Description
- CDU-C Description
- CDU-C+ Description
- CDU-D Description
- DXU Description
- DXU-21 Description
- ECU Description
- PSU -48 V Description
- PSU 230 V Description
- sTRU Single Transceiver Unit Description
- V3 Climate Unit Description
- Glossary
RBS 2103Macro Outdoor
Number of units: 1.
ACB – Alarm Collection Board
The ACB is the connection point in the cabinet for external alarms that are
connected t o the EAC U outside the cabinet.
Number of units: 1.
BFU – Battery Fuse Unit
The BFU provides a battery circuit breaker for one battery and connects the
battery to the +24 V DC busbar. The BFU also supplies +24 V DC to the ECU.
Number of units: 0 – 2.
CDU - Combining and Distribution Unit
The CDU is the interface between the transceivers and the antennas. Common
functions include TX combining, RX preamplifier and distribution, antenna
system supervision, and Tower M ounted Antenna (TMA) support.
Number of units: 1 – 3.
DXU - Distribution Sw itch Unit
The DXU is the central c ontrol unit for the RBS. Common functions include
distribution switching, BSC interface, timing, external alarm collection, local
bus control, and interface switching.
Note: In a master-extension configuration, The DXU is used only in the
master cabinet.
Number of units: 0 – 1.
ECU - Energy Control Unit
The ECU controls and supervises the power equipment and the climate control
equipment. The ECU also monitors the cabinet temperature.
Number of units: 1.
IDM - Internal Distribution Module
The IDM provides distribution and fusing for the +24V DC system voltage.
Number of units: 1.
10 (20)
EN/LZT 720 0 221 Ue n R1A